myLabComplianceCLIA compliance software · lab-consultants.comBook a demo

COLA inspection checklist: what to have ready

A preparation checklist for COLA-accredited laboratories, built from COLA's published list of survey documents and the CLIA regulations behind them.

Book a demo Visit mylabcompliance.io

About COLA surveys

COLA is a CMS-approved accrediting organization used by many physician office, clinic and hospital laboratories. Like CLIA certificates, COLA accreditation runs on a two-year cycle with an on-site survey. COLA's criteria incorporate CLIA requirements from 42 CFR Part 493 (eCFR), so preparing for COLA also prepares you for the CLIA regulations.

COLA publishes a list of COLA: Documents Necessary for the COLA Survey. Surveyors generally review records covering the period since your last survey, which for a typical lab means roughly two years of documentation. Confirm the current list and period with COLA before your survey.

Administrative documents

  • Current CLIA certificate and COLA accreditation documents.
  • State laboratory license, if your state requires one.
  • Test menu with methods and instruments, and any changes since the last survey.
  • Laboratory director's written delegation of responsibilities.
  • Previous survey report and evidence that cited deficiencies were corrected.

Personnel files

  • Qualification documents for the director, technical consultant, clinical consultant and testing personnel: diplomas, transcripts, licenses and certifications as applicable (42 CFR 493.1405–42 CFR 493.1425 for moderate complexity, 42 CFR 493.1441–42 CFR 493.1495 for high complexity).
  • Training records for each test before the person reported patient results.
  • Competency assessments for each person and test, at six months and one year for new staff and annually after, covering all six required procedures (42 CFR 493.1413, 42 CFR 493.1451). See competency tracking.

Procedures and documents

  • Procedure manual for every test, approved, signed and dated by the director, with changes approved before use (42 CFR 493.1251).
  • Manufacturer package inserts for reagents, controls and calibrators in use.
  • Retired procedures retained with dates of use. See document control.

Quality control and analytic records

  • All QC records, charts and logs, with evidence of review and corrective action (42 CFR 493.1256, 42 CFR 493.1282).
  • IQCP documents if used in place of default QC.
  • Method verification studies for each test introduced since the last survey (42 CFR 493.1253).
  • Calibration and calibration verification records (42 CFR 493.1255).
  • Instrument, equipment and pipette maintenance and function check records (42 CFR 493.1254).
  • Temperature logs for refrigerators, freezers, incubators and room storage, with corrective action for excursions.
  • Comparisons between instruments or methods used for the same test (42 CFR 493.1281). See QC and quality management.

Proficiency testing

  • PT enrollment for all regulated analytes, results for each event, signed attestations and evidence of review (42 CFR 493.801).
  • Investigations and corrective actions for unacceptable results.
  • Alternative accuracy assessments, twice a year, for tests without required PT (42 CFR 493.1236). See PT tracking.

Pre- and postanalytic records

  • Test requisitions and specimen handling and rejection records (42 CFR 493.1241, 42 CFR 493.1242).
  • Patient reports, critical value notifications and corrected reports (42 CFR 493.1291).
  • Reference lab agreements for referred testing.

Quality assessment

A four-step prep routine

  1. Inventory. Walk this list and note where each record lives.
  2. Gap check. Look for missing signatures, overdue competency, expired package inserts and QC without review.
  3. Correct and document. Fix gaps going forward and document why historical gaps happened; do not backdate.
  4. Keep it current. Move recurring tasks to a calendar so the next survey is not a project.

How myLabCompliance helps COLA labs

myLabCompliance lists a CLIA, CAP and COLA survey-ready program in its plans and has modules for personnel and competency, document control with version control and e-signatures, QC scheduling with Levey-Jennings charts and Westgard detection, QC investigations, instrument maintenance and calibration, PT tracking and a lab calendar. Keeping these records in one place makes the COLA document list a retrieval exercise rather than a scramble. For CLIA-only surveys, see the CLIA compliance checklist.

Frequently asked questions

How often does COLA survey laboratories?

COLA accreditation follows a two-year cycle with an on-site survey. Confirm current scheduling details with COLA.

What documents does COLA ask for?

COLA publishes a list of documents necessary for the survey, including personnel files, procedures, package inserts, QC and PT records, calibration and maintenance, temperature logs and quality assessment records.

Is COLA accreditation the same as CLIA certification?

No. CLIA is the federal requirement administered by CMS. COLA is a CMS-approved accreditor; accredited labs hold a CLIA Certificate of Accreditation.

How far back will a COLA surveyor look?

Typically records since the last survey, roughly two years. Check with COLA for your survey.

Can myLabCompliance prepare my COLA survey for me?

It organizes the records and reminders; your director and staff still perform and sign the work.

See myLabCompliance with your own lab's workflow

Book a demo and bring the compliance task that takes the most of your week. Product details are on mylabcompliance.io.

Book a demo

Sources: COLA: Documents Necessary for the COLA Survey · COLA · 42 CFR Part 493 (eCFR) · CMS State Operations Manual, Appendix C

This page is general information about laboratory regulations, not legal or regulatory advice. Confirm current requirements with CMS, your state agency, and your accrediting organization.