Laboratory quality management software for clinical labs

How clinical laboratories can run QC, corrective action and quality assessment in one system, and what CLIA requires of each.

Book a demo Visit mylabcompliance.io

Quality management under CLIA

CLIA's quality system requirements are in Subpart K of 42 CFR Part 493 (eCFR), starting at 42 CFR 493.1200. They require each nonwaived laboratory to establish and maintain written policies and procedures for a quality system covering general laboratory systems, the preanalytic, analytic and postanalytic phases, and ongoing quality assessment. The accreditors, CAP and COLA, build on the same structure. Laboratory quality management software is how many labs keep that system running day to day.

Quality control: what the regulation asks

42 CFR 493.1256 is the core QC rule. Key points:

  • The lab must have control procedures that monitor the accuracy and precision of the complete analytic process.
  • For each quantitative procedure, include two control materials of different concentrations at least once each day patient specimens are tested, unless the lab uses an alternative permitted by CMS such as an Individualized Quality Control Plan (IQCP), described in the CMS State Operations Manual, Appendix C.
  • For qualitative tests, include a negative and positive control each day of testing.
  • Control results must meet the lab's acceptability criteria before patient results are reported.
  • Control materials must be tested in the same manner as patient specimens.

When controls fail, 42 CFR 493.1282 requires documented corrective action. Calibration and calibration verification are covered in 42 CFR 493.1255, and comparison of results across instruments or methods twice a year in 42 CFR 493.1281.

Levey-Jennings charts and Westgard rules

A Levey-Jennings chart plots control results over time against the mean and standard deviation limits for that control lot. Westgard multirule QC applies a set of rules (for example 1-3s, 2-2s, R-4s, 4-1s and 10x) to decide whether a run is accepted or rejected and to spot shifts and trends. CLIA does not mandate a particular rule set; it requires the lab to define acceptability criteria and follow them. Charting and rule evaluation by hand on paper or in spreadsheets is slow and easy to get wrong, which is a main reason labs adopt QC software.

Corrective action and investigations

A good corrective action record answers: what failed, when, which patient results were affected, what was done, what the root cause was, and who reviewed it. Surveyors frequently look for QC rule violations followed by patient reporting with no documented action. Software should require an investigation record for each failure and route it for review.

Quality assessment

CLIA requires ongoing quality assessment for general systems (42 CFR 493.1239), preanalytic (42 CFR 493.1249), analytic (42 CFR 493.1289) and postanalytic systems (42 CFR 493.1299). In practice that means monitoring indicators, reviewing problems such as specimen rejections, QC failures, PT results, complaints and corrected reports, taking corrective action, and documenting discussion with staff. CAP also expects a written quality management plan.

Checklist: what to look for in QMS software

  • QC scheduling per test and instrument, with levels, lots and expiration.
  • Control limits from package inserts or lab-established data, by lot.
  • Levey-Jennings charts and rule-based flags.
  • Mandatory investigation and corrective action for failures, with review sign-off.
  • Instrument maintenance, calibration and calibration verification schedules.
  • Links from QC to procedures, personnel competency and PT, since inspectors trace across them.
  • Audit trail of entries and edits.
  • Reports for monthly QC review by the director or technical consultant.

How myLabCompliance handles quality management

According to mylabcompliance.io, the platform includes automated QC scheduling, control lot management, package insert limits by level, Levey-Jennings charts with statistical analysis, Westgard rule violation detection, QC failure investigation tracking with root cause and corrective action fields, IQCP workflows, instrument maintenance and calibration management, and inventory tracking for reagents and controls. These connect to personnel, documents and PT so a reviewer can follow a result from control run to corrective action.

Related guides: CLIA compliance checklist, proficiency testing tracking, document control.

Frequently asked questions

How many levels of QC does CLIA require?

For most quantitative nonwaived tests, 42 CFR 493.1256 requires two levels of control each day of patient testing, unless the lab uses a CMS-permitted alternative such as an IQCP.

What is an IQCP?

An Individualized Quality Control Plan is a CMS-recognized option, described in State Operations Manual Appendix C, that lets a lab set QC based on a documented risk assessment, QC plan and quality assessment.

Does CLIA require Westgard rules?

No specific rule set is required. Labs must define and follow acceptability criteria; Westgard multirules are a common way to do that.

What must be documented when QC fails?

Under 42 CFR 493.1282, corrective actions must be documented, including evaluation of patient results that may have been affected.

Does myLabCompliance chart QC?

Yes. mylabcompliance.io lists Levey-Jennings charts, statistical analysis and Westgard rule violation detection in its quality control module.

See myLabCompliance with your own lab's workflow

Book a demo and bring the compliance task that takes the most of your week. Product details are on mylabcompliance.io.

Book a demo

Sources: 42 CFR Part 493 (eCFR) · CMS State Operations Manual, Appendix C · mylabcompliance.io QC